PRODUCT DESCRIPTION |
||
TECHNICAL PARAMETERS | ||
Description | ABS/pc+PBT | |
Electric actuator | Nylon | |
Screw | SS304 | |
O-ring | Epdm/Fpm | |
Stem | pvdf+SS304/SS316/Brass | |
Valve Body | UPVC /CPVC/SS304/Brass | |
O-ring | Epdm/FPM | |
Valve Seat | PTFE | |
Ball | UPVC /CPVC/SS304/Brass |
WIRING DIAGRAM | |||||
Wiring Diagram JV01 Voltage:Dc3-6v/12v/9-24v |
|||||
1.Connecting SW to OPEN,the valve opens,getting the position,automatically power off, the vaiveremain fully open position | |||||
2.Connection SW to CLOSE,the valve close,getting the position,automatically power off,the valve remains side passes position(fully closed) | |||||
Wiring Diagram JV02 Voltage:DC3-6V/12V19-24V |
|||||
1.Connecting SW to OPEN,the valve opens.getting the position,automatically power off, the vaiveremain fully open position | |||||
2.Connection SW to CLOSED,the valve close,getting the position,automatically power off,the valve remains side passes position(fully closed) Note:AC24VIAC220V can only be usedfor JEVE-50K series electric valves | |||||
Wiring Diagram JV03 Voltage:DC3-6V/12V IADC9-24V IAC220V |
|||||
1.Connecting SW,the valve opens,getting the position,automatically power off,the valve remain fully open position | |||||
2.DisConnectingSW,the valve close,getting the position,automatically power off,the valve remains side passes position(fully closed) Note:When power is DC voltage and Red Wires is "+",Blue is "-" |
Wiring Diagram JV04 Voltage:DC3-6VIADC9-24VIAC220V |
||||||||
1.SW connecting,the valve open,getting the position and the power off automatically,the valve remains fully open/close position | ||||||||
2.SW disconnecting,the valve close,getting the position and power off automatically,the valveremains fully open/close position |
Common failures and processing methods
Fault cause:1.Can valve electric actuators be retrofitted to existing systems?
Yes, in many cases, valve electric actuators are designed to be retrofit-friendly. However, it's crucial to consider compatibility, sizing, and potential modifications to ensure a seamless integration into existing systems. Consulting with manufacturers and industry experts can provide guidance on retrofitting options.