12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator

Product Details
Customization: Available
Media: Oil Water Gas Acid
Material: UPVC Plastic
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
to see all verified strength labels (13)
  • 12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
  • 12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
  • 12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
  • 12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
  • 12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
  • 12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
Find Similar Products
  • Overview
  • Product Description
  • Unique FAQs
Overview

Basic Info.

Model NO.
m-02
Driving Mode
Electric
Nominal Pressure
PN1.0-32.0MPa
Channel
Straight Through Type
Structure
Flexible Ball Valve
Type
Flexible Ball Valve
Function
Control Flow Valve
Temperature
Normal Temperature
Application
Industrial Usage, Water Industrial Usage, Household Usage
Ambient Temperature
15-50 Celsius
Working Temperature
0-90 Celsius
Working Pressure
10 Bar Max.
Open/Close Time
5 Sec.
Rated Protection
IP67
Nominal Voltage
AC230V Working Current 0.5 AMPS
Specifications
Compact Design Light Weight Small Actuator with Fa
Size
1/2in 3/4in 1in
Pressure
Medium Pressure
Transport Package
Bubble Wrap Plus Carton
Specification
DC12V 24V AC110 220V 380V
Trademark
LEADWIN
Origin
China
Production Capacity
3000piece/Day

Packaging & Delivery

Package Size
33.00cm * 16.00cm * 20.50cm
Package Gross Weight
3.500kg
Lead Time
15 days (1 - 1000 Pieces)
To be negotiated ( > 1000 Pieces)

Product Description



Mini Electric Ball Valve 
Compact design and light weight, small electrical actuator with fail-safe function (NC)
Product Description
PRODUCT DESCRIPTION
12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
TECHNICAL PARAMETERS
Valve size NPT/BSP 1/4"3/8"1/2"3/4"1"1-1/4"(Optional)
Type Shutoff ballvalve,power is electricity
Maximum working pressure 1.0MPa
Circulation medium Fluid,air
Rated voltage DC3.5V DC5V DC12V DC24V AC/DC9-24V DC9-35V
AC110-230V (Optional)
Wiring diagram CR201 CR202 CR301 CR302 CR303 CR304 CR305 CR306
CR401CR501CR502CR701CR702CR703CR704(Optional)
Open/close time ≤500mA
Life time ≤5S
Valve body material 70000times(testingpressureis0.4MPa,medium is water)
Actuator material Brass SS304 SS316(Optional)
Sealing materia Engineering Plastics PPO
Actuator rotation 90°
Torque force 2N.m
Cable Length 0.5m
Environment temperature 15ºC~60ºC
Liquid temperature 2°ºC~90ºC
Manual operation YesNo(Optional)
Open/close indicator Yes No(Optional)
Protection class IP67
Certificate LVD,EMC,ROHS and some SS304 valves passed NSF61-G
Company quality
management system
SO9001:2015
WIRING DIAGRAM
                  CR201   WIRING   DIAGRAM(2   WIRES   CONTROL)
RD connect with positive,the BK connect with negative,the valve closed, the actuator automatically power off after in place,the valve remains fully closed position.
·BK connect with positive,the RD connect with negative,the valve open, the actuator automatically power off after in place,the valve remains fully open position
*Suitable Working Voltage:DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden
RD:Red  wire  BK:Black  wire  GR:Green  wire  BL:Blue  wire
    CR202  WIRING  DIAGRAM
  (2 wires control-"Capacitors return"in case of the power is failure)
·When SW is CLOSED,the valve OPEN,the actuator automatically power off after in place.
·When SW is OPEN,the valve CLOSED,the actuator automatically power off after in place.
*Suitable Working Voltage:DC5V,AC/DC9-24V,DC9-35V,AC110V-230V
*Exceeding the working voltage is forbidden
                  CR301  WIRING  DIAGRAM  (3  WIRES  CONTROL)
·RD&GR connect with positive,BK connect with negative
·When RD&SW connected,the valve open,the actuator automatically power off after in place,valve remains fully open position
·When GR&SW connected,the valve closed,the actuator automatically power off after in place,valve remains fully closed position.
*Suitable Working Voltage:DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden
CR302  WIRING  DIAGRAM  (3  WIRES  CONTROL)
RD connect with positive,the BK &GR connect with negative
·SW CLOSED,the valve OPEN,the actuator automatically power off after in place
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
*Suitable Working Voltage:DC9-35V
*Exceeding the working voltage is forbidden
CR303  WIRING  DIAGRAM  (3  WIRES  CONTROL)
  ·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve OPEN,the actuator automatically power   off after in place.
 ·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
*Suitable Working Voltage:AC/DC9-24V,DC9-35V,AC110-230V
*Exceeding the working voltage is forbidden
CR304  WIRING  DIAGRAM  (3  WIRES  CONTROL )
·RD&GR connected with positive,and the BK connected with negative
·When RD&SW connected,the valve closed,the actuator automatically
power off after in place,remains fully closed position
·When GR&SW connected,the valve open,the actuator automatically power off after in place,remains fully open position.
*Suitable Working Voltage:DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden
    CR305  WIRING  DIAGRAM
(3 wires control-"Capacitors return"in case of the power is failure)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve OPEN,the actuator automatically power off after in place.
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
*The valve will be auto closed when power is failure.
*Suitable Working Voltage:AC/DC9-24V,AC110-230V
*Exceeding the working voltage is forbidden
CR306  WIRING  DIAGRAM
 
(3  wires  control-"Capacitors  return"in  case  of the  power  is  failure)
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve CLOSED,the actuator automatically power off after in place
·SW OPEN,the valve OPEN,the actuator automatically power off after in place.
*The valve will be auto closed when power is failure.
*Suitable Working Voltage:AC/DC9-24V,AC110-230V
*Exceeding the working voltage is forbidden
CR401  WIRING  DIAGRAM  (4  WIRES  CONTROL)
1,RD&BK are connected to the power,GY&GR are connected to the
controlled wiring,
2,When the SW is closed,the valve open
3,When the SW is open,the valve closed
*Suitable Working Voltage:AC110V-230V
*Exceeding the working voltage is forbidden
The control wiring with power DC5V/DC24V,when muitiple motorized valves are working in paralled,must put the same color control wiring together,otherwise the valve could working
CR501  WIRING  DIAGRAM(WITH  FEEDBACK  SIGNAL)
12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
1.RD connect with positive,the BK connect with negative,
the valve closed,the actuator automatically power off after in place.

2.BK connect with positive,the RD connect with negative,
the valve open,the actuator automatically power off after in place.
3.GR&WT are connect when the valve open fully,YW&WT
are connect when the valve closed fully
*Suitable Working Voltage::DC5V,DC12V,DC24V
*Exceeding the working voltage is forbidden!
   CR502  WIRING  DIAGRAM
(with feedback  signal  and"Capacitors  return"in  case  of the  power  is failure)
  ·When  SW  is  closed  ,the  valve  open.the  actuator  automatically power  off  after  in  place
 ·When   SW   is   open,the  valve   closed,the   actuator  automatically power  off  after  in  place
*GR&WT  are  connect  when  the  valve  open  fully,YW  &WT  are connect  when  the  valve  closed  fully
 *Suitable     Working     Voltage:AC/DC9-24V,DC9-35V,AC110V-230V
*Exceeding  the  working  voltage   is  forbidden
   CR701  WIRING DIAGRAM
    (7 wires control with feedback signal)
---RD connect with positive
---GR connect with SW and negative wiring
---BK connect with negative wiring
---SW open.the valve open,and keeping fully open.
---SW closed.the valve closed,and keeping fully closed
----BL&GY connect with the valve's fully open signal wiring
---YW&WT connect with the valve's fully closed signal wiring
*Suitable Working Voltage:DC7-35V (wide input range voltage)
*Exceeding the working voltage is forbidden
Feedback with load ability:
The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A
   CR702 WIRING DIAGRAM
(7 wires control with feedback signal )
---RD connect with positive
---GR connect with SW and negative wiring
---BK connect with negative wiring
---SW open.the valve open,and keeping fully open.
---SW closed.the valve closed,and keeping fully closed.
----BL&GY connect with the valve's fully open signal wiring
---YW &WT connect with the valve's fully closed signal wiring.
*Suitable Working Voltage:DC7-35V (wide input range voltage)
*Exceeding the working voltage is forbidden
 Feedback with load ability:
 The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A
   CR702   WIRING   DIAGRAM
(7 wires control with feedback signal)
---RD connect with positive
---GR connect with SW and negative wiring
---BK connect with negative wiring
---SW open.the valve open,and keeping fully open.
---SW closed.the valve closed,and keeping fully closed.
---BL&GY connect with the valve's fully open signal wiring
---YW &WT connect with the valve's fully closed signal wiring.
*Suitable Working Voltage:DC7-35V (wide input range voltage)
*Exceeding the working voltage is forbidden
 Feedback with load ability:
 The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A
 CR703   WIRING   DIAGRAM
(7 wires control with feedback signal)
12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve OPEN,the actuator automatically power
off after in place
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place.
·BL&GY connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.
*Suitable Working Voltage:AC/DC9-24V,DC9-35V
*Exceeding the working voltage is forbidden
 CR704   WIRING   DIAGRAM
(7 wires control with feedback signal)
·RD&BK are connected to the power,GR&BL are connected to the controlled  wiring.
·When the SWis closed,the valve open
·When the SW is open,the valve closed
·GR&WT connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.
Suitable Working Voltage::AC110V-230V
*Exceeding the working voltage is forbidden
 
CR705   WIRING   DIAGRAM
(with feedback signal and"Capacitors return"in case of the power is failure)
12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
·RD&GR connect with positive,the BK connect with negative.

·SW CLOSED,the valve OPEN,the actuator automatically power
off after in place.
·SW OPEN,the valve CLOSED,the actuator automatically power
off after in place.
·When external power is off,the valve closed,the actuator automatically
power off after in place.
·BL&GY connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.

*Suitable Working Voltage:AC/DC9-24V,AC110-230V

*Exceeding the working voltage is forbidden
CR706   WIRING   DIAGRAM
(with feedback signal and"Capacitors return"in case of the power is failure)
12V DC 2 Way Waterproof Double Union UPVC Water Plastic Motorized Ball Valve with Electric Actuator
·RD&GR connect with positive,the BK connect with negative.
·SW CLOSED,the valve CLOSED,the actuator automatically power
off after in place.
·SW OPEN,the valve OPEN,the actuator automatically power
off after in place.
·When external power is off,the valve closed,the actuator automatically
power off after in place.
·BL&GY connect with the valve's fully open signal wiring
·YW&WT connect with the valve's fully closed signal wiring.

*Suitable Working Voltage:AC/DC9-24V,AC110-230V

*Exceeding the working voltage is forbidden

About the"Capacitors return"function,there are twokinds of valve:normally closed and normally open.
Normally closed:

the valve will be auto closed when the power is off(without power);the valve will be auto open when the power is on.
Normally open:
the valve will be auto open when the power is off(without power);the valve will be auto closed when the power is on.
Kindly Remind:
please charge the motorized ball valve before using.
Unique FAQs

1.What is the most common type of actuation for 3/4" valves?
Electric and pneumatic actuators are commonly used, depending on the application requirements and operational environment.

2.How do I choose the right actuator for my 3/4" valve?
Consider factors such as the type of fluid, required response time, frequency of operation, and available energy sources.

3.Can I retrofit a manual valve to an automated system?
Yes, many manual valves can be retrofitted with electric or pneumatic actuators, but compatibility should be verified.

4.What are the maintenance requirements for actuated valves?
Regular inspections of the actuator, valve seals, and connections are necessary to ensure optimal performance and prevent leaks.

5.Are there safety concerns with using actuated valves?
Yes, it's important to implement safety measures such as fail-safe mechanisms and regular system checks to ensure safe operation.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier