Customization: | Available |
---|---|
Media: | Oil Water Gas Acid |
Material: | Stainless Steel |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PRODUCT DESCRIPTION |
||
TECHNICAL PARAMETERS | ||
Valve size | NPT/BSP 1/4"3/8"1/2"3/4"1"1-1/4"(Optional) | |
Type | Shutoff ballvalve,power is electricity | |
Maximum working pressure | 1.0MPa | |
Circulation medium | Fluid,air | |
Rated voltage | DC3.5V DC5V DC12V DC24V AC/DC9-24V DC9-35V AC110-230V (Optional) |
|
Wiring diagram | CR201 CR202 CR301 CR302 CR303 CR304 CR305 CR306 CR401CR501CR502CR701CR702CR703CR704(Optional) |
|
Open/close time | ≤500mA | |
Life time | ≤5S | |
Valve body material | 70000times(testingpressureis0.4MPa,medium is water) | |
Actuator material | Brass SS304 SS316(Optional) | |
Sealing materia | Engineering Plastics PPO | |
Actuator rotation | 90° | |
Torque force | 2N.m | |
Cable Length | 0.5m | |
Environment temperature | 15ºC~60ºC | |
Liquid temperature | 2°ºC~90ºC | |
Manual operation | YesNo(Optional) | |
Open/close indicator | Yes No(Optional) | |
Protection class | IP67 | |
Certificate | LVD,EMC,ROHS and some SS304 valves passed NSF61-G | |
Company quality management system |
SO9001:2015 |
WIRING DIAGRAM | |||||
CR201 WIRING DIAGRAM(2 WIRES CONTROL) | |||||
RD connect with positive,the BK connect with negative,the valve closed, the actuator automatically power off after in place,the valve remains fully closed position. | |||||
·BK connect with positive,the RD connect with negative,the valve open, the actuator automatically power off after in place,the valve remains fully open position | |||||
*Suitable Working Voltage:DC5V,DC12V,DC24V | |||||
*Exceeding the working voltage is forbidden | |||||
RD:Red wire BK:Black wire GR:Green wire BL:Blue wire | |||||
CR202 WIRING DIAGRAM | |||||
(2 wires control-"Capacitors return"in case of the power is failure) | |||||
·When SW is CLOSED,the valve OPEN,the actuator automatically power off after in place. | |||||
·When SW is OPEN,the valve CLOSED,the actuator automatically power off after in place. | |||||
*Suitable Working Voltage:DC5V,AC/DC9-24V,DC9-35V,AC110V-230V *Exceeding the working voltage is forbidden |
|||||
CR301 WIRING DIAGRAM (3 WIRES CONTROL) | |||||
·RD&GR connect with positive,BK connect with negative | |||||
·When RD&SW connected,the valve open,the actuator automatically power off after in place,valve remains fully open position | |||||
·When GR&SW connected,the valve closed,the actuator automatically power off after in place,valve remains fully closed position. | |||||
*Suitable Working Voltage:DC5V,DC12V,DC24V *Exceeding the working voltage is forbidden |
CR302 WIRING DIAGRAM (3 WIRES CONTROL) | ||||||||
RD connect with positive,the BK &GR connect with negative | ||||||||
·SW CLOSED,the valve OPEN,the actuator automatically power off after in place | ||||||||
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place. | ||||||||
*Suitable Working Voltage:DC9-35V | ||||||||
*Exceeding the working voltage is forbidden | ||||||||
CR303 WIRING DIAGRAM (3 WIRES CONTROL) | ||||||||
·RD&GR connect with positive,the BK connect with negative. ·SW CLOSED,the valve OPEN,the actuator automatically power off after in place. |
||||||||
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place. | ||||||||
*Suitable Working Voltage:AC/DC9-24V,DC9-35V,AC110-230V *Exceeding the working voltage is forbidden |
||||||||
CR304 WIRING DIAGRAM (3 WIRES CONTROL ) | ||||||||
·RD&GR connected with positive,and the BK connected with negative ·When RD&SW connected,the valve closed,the actuator automatically |
||||||||
power off after in place,remains fully closed position | ||||||||
·When GR&SW connected,the valve open,the actuator automatically power off after in place,remains fully open position. *Suitable Working Voltage:DC5V,DC12V,DC24V *Exceeding the working voltage is forbidden |
CR305 WIRING DIAGRAM | ||||||
(3 wires control-"Capacitors return"in case of the power is failure) | ||||||
·RD&GR connect with positive,the BK connect with negative. ·SW CLOSED,the valve OPEN,the actuator automatically power off after in place. |
||||||
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place. | ||||||
*The valve will be auto closed when power is failure. *Suitable Working Voltage:AC/DC9-24V,AC110-230V *Exceeding the working voltage is forbidden |
||||||
CR306 WIRING DIAGRAM |
||||||
(3 wires control-"Capacitors return"in case of the power is failure) | ||||||
·RD&GR connect with positive,the BK connect with negative. ·SW CLOSED,the valve CLOSED,the actuator automatically power off after in place |
||||||
·SW OPEN,the valve OPEN,the actuator automatically power off after in place. | ||||||
*The valve will be auto closed when power is failure. *Suitable Working Voltage:AC/DC9-24V,AC110-230V *Exceeding the working voltage is forbidden |
CR401 WIRING DIAGRAM (4 WIRES CONTROL) | |||
1,RD&BK are connected to the power,GY&GR are connected to the controlled wiring, |
|||
2,When the SW is closed,the valve open 3,When the SW is open,the valve closed *Suitable Working Voltage:AC110V-230V |
|||
*Exceeding the working voltage is forbidden | |||
The control wiring with power DC5V/DC24V,when muitiple motorized valves are working in paralled,must put the same color control wiring together,otherwise the valve could working | |||
CR501 WIRING DIAGRAM(WITH FEEDBACK SIGNAL) | |||
1.RD connect with positive,the BK connect with negative, | |||
the valve closed,the actuator automatically power off after in place. 2.BK connect with positive,the RD connect with negative, |
|||
the valve open,the actuator automatically power off after in place. 3.GR&WT are connect when the valve open fully,YW&WT |
|||
are connect when the valve closed fully | |||
*Suitable Working Voltage::DC5V,DC12V,DC24V *Exceeding the working voltage is forbidden! |
CR502 WIRING DIAGRAM | |||
(with feedback signal and"Capacitors return"in case of the power is failure) | |||
·When SW is closed ,the valve open.the actuator automatically power off after in place | |||
·When SW is open,the valve closed,the actuator automatically power off after in place | |||
*GR&WT are connect when the valve open fully,YW &WT are connect when the valve closed fully | |||
*Suitable Working Voltage:AC/DC9-24V,DC9-35V,AC110V-230V *Exceeding the working voltage is forbidden |
|||
CR701 WIRING DIAGRAM | |||
(7 wires control with feedback signal) | |||
---RD connect with positive | |||
---GR connect with SW and negative wiring | |||
---BK connect with negative wiring | |||
---SW open.the valve open,and keeping fully open. | |||
---SW closed.the valve closed,and keeping fully closed | |||
----BL&GY connect with the valve's fully open signal wiring | |||
---YW&WT connect with the valve's fully closed signal wiring | |||
*Suitable Working Voltage:DC7-35V (wide input range voltage) | |||
*Exceeding the working voltage is forbidden | |||
Feedback with load ability: The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A |
CR702 WIRING DIAGRAM | ||||||||
(7 wires control with feedback signal ) | ||||||||
---RD connect with positive | ||||||||
---GR connect with SW and negative wiring ---BK connect with negative wiring |
||||||||
---SW open.the valve open,and keeping fully open. | ||||||||
---SW closed.the valve closed,and keeping fully closed. | ||||||||
----BL&GY connect with the valve's fully open signal wiring ---YW &WT connect with the valve's fully closed signal wiring. *Suitable Working Voltage:DC7-35V (wide input range voltage) *Exceeding the working voltage is forbidden Feedback with load ability: |
||||||||
The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A | ||||||||
CR702 WIRING DIAGRAM | ||||||||
(7 wires control with feedback signal) | ||||||||
---RD connect with positive | ||||||||
---GR connect with SW and negative wiring ---BK connect with negative wiring |
||||||||
---SW open.the valve open,and keeping fully open. | ||||||||
---SW closed.the valve closed,and keeping fully closed. | ||||||||
---BL&GY connect with the valve's fully open signal wiring ---YW &WT connect with the valve's fully closed signal wiring. *Suitable Working Voltage:DC7-35V (wide input range voltage) *Exceeding the working voltage is forbidden Feedback with load ability: |
||||||||
The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A |
CR703 WIRING DIAGRAM | ||||||
(7 wires control with feedback signal) | ||||||
·RD&GR connect with positive,the BK connect with negative. ·SW CLOSED,the valve OPEN,the actuator automatically power |
||||||
off after in place | ||||||
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place. | ||||||
·BL&GY connect with the valve's fully open signal wiring ·YW&WT connect with the valve's fully closed signal wiring. *Suitable Working Voltage:AC/DC9-24V,DC9-35V *Exceeding the working voltage is forbidden |
||||||
CR704 WIRING DIAGRAM | ||||||
(7 wires control with feedback signal) | ||||||
·RD&BK are connected to the power,GR&BL are connected to the controlled wiring. | ||||||
·When the SWis closed,the valve open ·When the SW is open,the valve closed |
||||||
·GR&WT connect with the valve's fully open signal wiring ·YW&WT connect with the valve's fully closed signal wiring. |
||||||
Suitable Working Voltage::AC110V-230V | ||||||
*Exceeding the working voltage is forbidden |
CR705 WIRING DIAGRAM | |
(with feedback signal and"Capacitors return"in case of the power is failure) | |
·RD&GR connect with positive,the BK connect with negative. ·SW CLOSED,the valve OPEN,the actuator automatically power |
|
off after in place. | |
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place. |
|
·When external power is off,the valve closed,the actuator automatically power off after in place. |
|
·BL&GY connect with the valve's fully open signal wiring | |
·YW&WT connect with the valve's fully closed signal wiring. *Suitable Working Voltage:AC/DC9-24V,AC110-230V *Exceeding the working voltage is forbidden |
|
CR706 WIRING DIAGRAM | |
(with feedback signal and"Capacitors return"in case of the power is failure) | |
·RD&GR connect with positive,the BK connect with negative. | |
·SW CLOSED,the valve CLOSED,the actuator automatically power off after in place. |
|
·SW OPEN,the valve OPEN,the actuator automatically power off after in place. |
|
·When external power is off,the valve closed,the actuator automatically power off after in place. |
|
·BL&GY connect with the valve's fully open signal wiring | |
·YW&WT connect with the valve's fully closed signal wiring. *Suitable Working Voltage:AC/DC9-24V,AC110-230V *Exceeding the working voltage is forbidden |
1.Can valve electric actuators be retrofitted to existing systems?
Absolutely! Our electric actuators are retrofit-friendly and designed for compatibility and ease of integration. For optimal results, consult with manufacturers and experts to adapt existing systems seamlessly.
2. What role do valve electric actuators play in preventing leaks and spills in industrial processes?
Essential for safety, our valve electric actuators provide precise control, preventing leaks and spills. They enhance overall process integrity, reducing environmental risks and promoting operational safety.
3. Are there advancements in remote monitoring and control of valve electric actuators?
Indeed! Embrace the future with smart actuators, offering remote monitoring and control through cutting-edge connectivity features. This advancement boosts flexibility and operational efficiency.
4. How do valve electric actuators contribute to process optimization in manufacturing plants?
By offering precise fluid flow control, our actuators maximize efficiency and quality, minimizing waste and optimizing manufacturing processes.
5. What measures are in place to ensure the cybersecurity of smart valve electric actuators?
To safeguard against cyber threats, manufacturers implement robust security measures, including encryption and authentication protocols, ensuring your systems stay secure and protected.
Want More Information About Smart Mini Electric Actuator Valve?
Inquiry Us: Reach out today! To Get The Best Price: Connect with us for unbeatable offers and value!