Customization: | Available |
---|---|
Media: | Oil Water Gas Acid |
Material: | Stainless Steel |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PRODUCT DESCRIPTION |
||
TECHNICAL PARAMETERS | ||
Valve size | NPT/BSP 1/4"3/8"1/2"3/4"1"1-1/4"(Optional) | |
Type | Shutoff ballvalve,power is electricity | |
Maximum working pressure | 1.0MPa | |
Circulation medium | Fluid,air | |
Rated voltage | DC3.5V DC5V DC12V DC24V AC/DC9-24V DC9-35V AC110-230V (Optional) |
|
Wiring diagram | CR201 CR202 CR301 CR302 CR303 CR304 CR305 CR306 CR401CR501CR502CR701CR702CR703CR704(Optional) |
|
Open/close time | ≤500mA | |
Life time | ≤5S | |
Valve body material | 70000times(testingpressureis0.4MPa,medium is water) | |
Actuator material | Brass SS304 SS316(Optional) | |
Sealing materia | Engineering Plastics PPO | |
Actuator rotation | 90° | |
Torque force | 2N.m | |
Cable Length | 0.5m | |
Environment temperature | 15ºC~60ºC | |
Liquid temperature | 2°ºC~90ºC | |
Manual operation | YesNo(Optional) | |
Open/close indicator | Yes No(Optional) | |
Protection class | IP67 | |
Certificate | LVD,EMC,ROHS and some SS304 valves passed NSF61-G | |
Company quality management system |
SO9001:2015 |
WIRING DIAGRAM | |||||
CR201 WIRING DIAGRAM(2 WIRES CONTROL) | |||||
RD connect with positive,the BK connect with negative,the valve closed, the actuator automatically power off after in place,the valve remains fully closed position. | |||||
·BK connect with positive,the RD connect with negative,the valve open, the actuator automatically power off after in place,the valve remains fully open position | |||||
*Suitable Working Voltage:DC5V,DC12V,DC24V | |||||
*Exceeding the working voltage is forbidden | |||||
RD:Red wire BK:Black wire GR:Green wire BL:Blue wire | |||||
CR202 WIRING DIAGRAM | |||||
(2 wires control-"Capacitors return"in case of the power is failure) | |||||
·When SW is CLOSED,the valve OPEN,the actuator automatically power off after in place. | |||||
·When SW is OPEN,the valve CLOSED,the actuator automatically power off after in place. | |||||
*Suitable Working Voltage:DC5V,AC/DC9-24V,DC9-35V,AC110V-230V *Exceeding the working voltage is forbidden |
|||||
CR301 WIRING DIAGRAM (3 WIRES CONTROL) | |||||
·RD&GR connect with positive,BK connect with negative | |||||
·When RD&SW connected,the valve open,the actuator automatically power off after in place,valve remains fully open position | |||||
·When GR&SW connected,the valve closed,the actuator automatically power off after in place,valve remains fully closed position. | |||||
*Suitable Working Voltage:DC5V,DC12V,DC24V *Exceeding the working voltage is forbidden |
CR302 WIRING DIAGRAM (3 WIRES CONTROL) | ||||||||
RD connect with positive,the BK &GR connect with negative | ||||||||
·SW CLOSED,the valve OPEN,the actuator automatically power off after in place | ||||||||
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place. | ||||||||
*Suitable Working Voltage:DC9-35V | ||||||||
*Exceeding the working voltage is forbidden | ||||||||
CR303 WIRING DIAGRAM (3 WIRES CONTROL) | ||||||||
·RD&GR connect with positive,the BK connect with negative. ·SW CLOSED,the valve OPEN,the actuator automatically power off after in place. |
||||||||
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place. | ||||||||
*Suitable Working Voltage:AC/DC9-24V,DC9-35V,AC110-230V *Exceeding the working voltage is forbidden |
||||||||
CR304 WIRING DIAGRAM (3 WIRES CONTROL ) | ||||||||
·RD&GR connected with positive,and the BK connected with negative ·When RD&SW connected,the valve closed,the actuator automatically |
||||||||
power off after in place,remains fully closed position | ||||||||
·When GR&SW connected,the valve open,the actuator automatically power off after in place,remains fully open position. *Suitable Working Voltage:DC5V,DC12V,DC24V *Exceeding the working voltage is forbidden |
CR305 WIRING DIAGRAM | ||||||
(3 wires control-"Capacitors return"in case of the power is failure) | ||||||
·RD&GR connect with positive,the BK connect with negative. ·SW CLOSED,the valve OPEN,the actuator automatically power off after in place. |
||||||
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place. | ||||||
*The valve will be auto closed when power is failure. *Suitable Working Voltage:AC/DC9-24V,AC110-230V *Exceeding the working voltage is forbidden |
||||||
CR306 WIRING DIAGRAM |
||||||
(3 wires control-"Capacitors return"in case of the power is failure) | ||||||
·RD&GR connect with positive,the BK connect with negative. ·SW CLOSED,the valve CLOSED,the actuator automatically power off after in place |
||||||
·SW OPEN,the valve OPEN,the actuator automatically power off after in place. | ||||||
*The valve will be auto closed when power is failure. *Suitable Working Voltage:AC/DC9-24V,AC110-230V *Exceeding the working voltage is forbidden |
CR401 WIRING DIAGRAM (4 WIRES CONTROL) | |||
1,RD&BK are connected to the power,GY&GR are connected to the controlled wiring, |
|||
2,When the SW is closed,the valve open 3,When the SW is open,the valve closed *Suitable Working Voltage:AC110V-230V |
|||
*Exceeding the working voltage is forbidden | |||
The control wiring with power DC5V/DC24V,when muitiple motorized valves are working in paralled,must put the same color control wiring together,otherwise the valve could working | |||
CR501 WIRING DIAGRAM(WITH FEEDBACK SIGNAL) | |||
1.RD connect with positive,the BK connect with negative, | |||
the valve closed,the actuator automatically power off after in place. 2.BK connect with positive,the RD connect with negative, |
|||
the valve open,the actuator automatically power off after in place. 3.GR&WT are connect when the valve open fully,YW&WT |
|||
are connect when the valve closed fully | |||
*Suitable Working Voltage::DC5V,DC12V,DC24V *Exceeding the working voltage is forbidden! |
CR502 WIRING DIAGRAM | |||
(with feedback signal and"Capacitors return"in case of the power is failure) | |||
·When SW is closed ,the valve open.the actuator automatically power off after in place | |||
·When SW is open,the valve closed,the actuator automatically power off after in place | |||
*GR&WT are connect when the valve open fully,YW &WT are connect when the valve closed fully | |||
*Suitable Working Voltage:AC/DC9-24V,DC9-35V,AC110V-230V *Exceeding the working voltage is forbidden |
|||
CR701 WIRING DIAGRAM | |||
(7 wires control with feedback signal) | |||
---RD connect with positive | |||
---GR connect with SW and negative wiring | |||
---BK connect with negative wiring | |||
---SW open.the valve open,and keeping fully open. | |||
---SW closed.the valve closed,and keeping fully closed | |||
----BL&GY connect with the valve's fully open signal wiring | |||
---YW&WT connect with the valve's fully closed signal wiring | |||
*Suitable Working Voltage:DC7-35V (wide input range voltage) | |||
*Exceeding the working voltage is forbidden | |||
Feedback with load ability: The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A |
CR702 WIRING DIAGRAM | ||||||||
(7 wires control with feedback signal ) | ||||||||
---RD connect with positive | ||||||||
---GR connect with SW and negative wiring ---BK connect with negative wiring |
||||||||
---SW open.the valve open,and keeping fully open. | ||||||||
---SW closed.the valve closed,and keeping fully closed. | ||||||||
----BL&GY connect with the valve's fully open signal wiring ---YW &WT connect with the valve's fully closed signal wiring. *Suitable Working Voltage:DC7-35V (wide input range voltage) *Exceeding the working voltage is forbidden Feedback with load ability: |
||||||||
The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A | ||||||||
CR702 WIRING DIAGRAM | ||||||||
(7 wires control with feedback signal) | ||||||||
---RD connect with positive | ||||||||
---GR connect with SW and negative wiring ---BK connect with negative wiring |
||||||||
---SW open.the valve open,and keeping fully open. | ||||||||
---SW closed.the valve closed,and keeping fully closed. | ||||||||
---BL&GY connect with the valve's fully open signal wiring ---YW &WT connect with the valve's fully closed signal wiring. *Suitable Working Voltage:DC7-35V (wide input range voltage) *Exceeding the working voltage is forbidden Feedback with load ability: |
||||||||
The Max.off voltage:DC36V AC220V The Max.off current:≤0.4A |
CR703 WIRING DIAGRAM | ||||||
(7 wires control with feedback signal) | ||||||
·RD&GR connect with positive,the BK connect with negative. ·SW CLOSED,the valve OPEN,the actuator automatically power |
||||||
off after in place | ||||||
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place. | ||||||
·BL&GY connect with the valve's fully open signal wiring ·YW&WT connect with the valve's fully closed signal wiring. *Suitable Working Voltage:AC/DC9-24V,DC9-35V *Exceeding the working voltage is forbidden |
||||||
CR704 WIRING DIAGRAM | ||||||
(7 wires control with feedback signal) | ||||||
·RD&BK are connected to the power,GR&BL are connected to the controlled wiring. | ||||||
·When the SWis closed,the valve open ·When the SW is open,the valve closed |
||||||
·GR&WT connect with the valve's fully open signal wiring ·YW&WT connect with the valve's fully closed signal wiring. |
||||||
Suitable Working Voltage::AC110V-230V | ||||||
*Exceeding the working voltage is forbidden |
CR705 WIRING DIAGRAM | |
(with feedback signal and"Capacitors return"in case of the power is failure) | |
·RD&GR connect with positive,the BK connect with negative. ·SW CLOSED,the valve OPEN,the actuator automatically power |
|
off after in place. | |
·SW OPEN,the valve CLOSED,the actuator automatically power off after in place. |
|
·When external power is off,the valve closed,the actuator automatically power off after in place. |
|
·BL&GY connect with the valve's fully open signal wiring | |
·YW&WT connect with the valve's fully closed signal wiring. *Suitable Working Voltage:AC/DC9-24V,AC110-230V *Exceeding the working voltage is forbidden |
|
CR706 WIRING DIAGRAM | |
(with feedback signal and"Capacitors return"in case of the power is failure) | |
·RD&GR connect with positive,the BK connect with negative. | |
·SW CLOSED,the valve CLOSED,the actuator automatically power off after in place. |
|
·SW OPEN,the valve OPEN,the actuator automatically power off after in place. |
|
·When external power is off,the valve closed,the actuator automatically power off after in place. |
|
·BL&GY connect with the valve's fully open signal wiring | |
·YW&WT connect with the valve's fully closed signal wiring. *Suitable Working Voltage:AC/DC9-24V,AC110-230V *Exceeding the working voltage is forbidden |
1.Can valve electric actuators be retrofitted to existing systems?
Yes, in many cases, valve electric actuators are designed to be retrofit-friendly. However, it's crucial to consider compatibility, sizing, and potential modifications to ensure a seamless integration into existing systems. Consulting with manufacturers and industry experts can provide guidance on retrofitting options.