Customization: | Available |
---|---|
Media: | Oil Water Gas Acid |
Material: | Brass |
Still deciding? Get samples of US$ 57.69/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PRODUCT DESCRIPTION |
||
TECHNICAL PARAMETERS | ||
Product size | NPT/BSP 1/4", 3/8' 1/2'',3/4'', 1" (Optional) | |
Maximum working pressure | 1.5 MPa | |
Circulation medium | Fluid, Air | |
Rated voltage | AC/DC9-24V, AC110-230V | |
Working current | ≤500MA | |
Open/close time | ≤7Sec | |
Life time | 70000 times | |
Valve Body material | Brass, Nickel plated, Brass,304/306 Stainless steel (Optional) | |
Actuator material | Engineering Plastics | |
Sealing material | EPDM & PTFE | |
Actuator rotation | 90° | |
Max. torque force | 4 Nm | |
Cable Length | 0.5m,1.5m(Optional) | |
Environment temperature | -15ºC~50ºC | |
Liquid temperature | 2ºC~90ºC | |
Manual override | No | |
Indicator | Yes | |
Protection class | IP67 | |
Time control range |
0 H : 0M :0S --99 H 59 M 59 S |
DN | SIZE | inner box size/cm | outer box size /cm | piece/box | gross weight |
DN8 | 1/4" | 11x8.5x7.5 | 39x35x20 | 30 | |
DN10 | 3/8" | 11x8.5x7.5 | 39x35x20 | 30 | |
DN15 | 1/2" | 11x8.5x7.5 | 39x35x20 | 30 | 12.5 |
DN20 | 3/4" | 11x8.5x7.5 | 39x35x20 | 20 | 13.7 |
DN25 | 1" | 14.1*8*8.5 | 39x35x20 | 20 | 12.9 |
WIRING DIAGRAM | |||||
Wiring Diagram JV01 Voltage:Dc3-6v/12v/9-24v |
|||||
1.Connecting SW to OPEN,the valve opens,getting the position,automatically power off, the vaiveremain fully open position | |||||
2.Connection SW to CLOSE,the valve close,getting the position,automatically power off,the valve remains side passes position(fully closed) | |||||
Wiring Diagram JV02 Voltage:DC3-6V/12V19-24V |
|||||
1.Connecting SW to OPEN,the valve opens.getting the position,automatically power off, the vaiveremain fully open position | |||||
2.Connection SW to CLOSED,the valve close,getting the position,automatically power off,the valve remains side passes position(fully closed) Note:AC24VIAC220V can only be usedfor JEVE-50K series electric valves | |||||
Wiring Diagram JV03 Voltage:DC3-6V/12V IADC9-24V IAC220V |
|||||
1.Connecting SW,the valve opens,getting the position,automatically power off,the valve remain fully open position | |||||
2.DisConnectingSW,the valve close,getting the position,automatically power off,the valve remains side passes position(fully closed) Note:When power is DC voltage and Red Wires is "+",Blue is "-" |
Wiring Diagram JV04 Voltage:DC3-6VIADC9-24VIAC220V |
||||||||
1.SW connecting,the valve open,getting the position and the power off automatically,the valve remains fully open/close position | ||||||||
2.SW disconnecting,the valve close,getting the position and power off automatically,the valveremains fully open/close position |
Product application
Economic Mini Motorized Ball Valve in 2 or 3 way /Timer Control Motorized Ball Valve in Grey or Black housing / Water Leak Alarm & Automatic shut off system(Actuator color optional, valve material optional.(Brass, stainless steel,nickel brass,PVC...)
1. Auto drain & Water cooling system
2. Electric brewing system
3. Heating & Cooling HAVC system
4. Water cooling bleed system
5. Rain water harvesting
6. Solar heating,undefloor heating
7. Irrigation system
8. Leak detection & water shut off system
9. Water saving system
10. And some other automatic control system.....
Common failures and processing methods
1.Can valve electric actuators be retrofitted to existing systems?
Yes, in many cases, valve electric actuators are designed to be retrofit-friendly. However, it's crucial to consider compatibility, sizing, and potential modifications to ensure a seamless integration into existing systems. Consulting with manufacturers and industry experts can provide guidance on retrofitting options.
2.What role do valve electric actuators play in preventing leaks and spills in industrial processes?
Valve electric actuators, with their precise control capabilities, play a crucial role in preventing leaks and spills. By swiftly and accurately modulating valve positions, these actuators contribute to the overall safety and integrity of industrial processes, reducing the risk of environmental incidents.
3.Are there advancements in remote monitoring and control of valve electric actuators?
Yes, advancements in communication technologies have facilitated remote monitoring and control of valve electric actuators. Smart actuators, equipped with connectivity features, allow operators to monitor and adjust valve positions remotely, enhancing operational flexibility and efficiency.
4.How do valve electric actuators contribute to process optimization in manufacturing plants?
Valve electric actuators contribute to process optimization by providing precise control over fluid flow. This level of control enhances the overall efficiency of manufacturing processes, ensuring consistent quality and minimizing wastage.
5.What measures are in place to ensure the cybersecurity of smart valve electric actuators?
As smart technologies become more prevalent, ensuring the cybersecurity of valve electric actuators is paramount. Manufacturers implement robust security measures, including encryption and authentication protocols, to safeguard against cyber threats and unauthorized access.
Want More Infomation About Smart Mini Electric Actuator Valve ?
Inquiry Us To Get A Best Price!